Sign In | Join Free | My disqueenfrance.com
China ZHEJIANG YOMIN ELECTRIC CO.,LTD logo
ZHEJIANG YOMIN ELECTRIC CO.,LTD
ZHEJIANG YOMIN ELECTRIC CO.,LTD Professional Instrumentation Manufacturers
Site Member

9 Years

Home > Energy Meter Test Bench >

Meter Test Bench Automatic Change To Calibrate / Test Line And Neutral 16 Positions

ZHEJIANG YOMIN ELECTRIC CO.,LTD

Meter Test Bench Automatic Change To Calibrate / Test Line And Neutral 16 Positions

Brand Name : YOMIN

Model Number : YM-S3600

Certification : CE/RoHS

Place of Origin : Zhejiang , China (Mainland)

MOQ : 100 Pieces

Price : Negotiation

Payment Terms : L/C , T/T , Western Union , Paypal

Supply Ability : 60000 per month

Delivery Time : 5-30 working days after receiving payment

Packaging Details : polybag+paper box+carton

Measuring Energy Range : Max120A

Power : Electronic

Output Voltage : 0~275/300V

phase adjustment : 0 to 359.9°

Voltage output capacity : >15VA per postion

Usage : Auto Testing Machine

Contact Now

METER TEST BENCH AUTOMATIC CHANGE TO CALIBRATE / TEST LINE AND NEUTRAL(16 POSITIONS)

Description

● Suitable design, good figure. The frame for meters and the body frame are fully made by special aluminum alloy. The table board is composed of fireproofing and heat-proof fiber materials. The whole device is in soft color and good figure.
● The coexistence of special small keyboard and PCs, convenience to use. This device can be equipped with mobile portable small keyboard, the figure and handle of the small keyboard is similar to the keyboard of PCs. With every key identified clearly and LCD screen, the work status is clear at a glance. Easy operation will carry out. The PC's control software has clear levels, beautiful interface and easy use.
● High level of autoimmunization. When checking the electric meters, you only need hang the meters manual and adjust the photoelectric sampler and setup the parameters correctly then all of the checking items (including warm-up, dormant test, startup test, standard wind age measurement, basic error measurement) will be controlled by PCs automatically and fulfill at once time. The checking program can be designed according to the national regulations or user-defined.
● Photoelectric sampler can realize three-dimensional adjustment. It can sample the turntable signal of rotary electric meters and the stroboscopic signal of electronic electric meters. The photoelectric head also has the function of auto-turning.
● The error handling systems can receive the signals of the photoelectric sampler, the output pulse of installation electric meters and high frequency pulse signals of standard electric meters.
● The electric meters of same type (same in phase line, rated voltage, rated current) and different constants can be checked at the same time (limited in 3 constants).
● It can check the communication functions of the 485 interface of the multi-function electric meters, demand errors and clock errors (clock signal outputs of the meters are needed).
● Location of the marker area of the turntable of the rotary electric meters is automatically, that make it convenient for the dormant or startup test.
● It can be appended 2-21 harmonic at the base band wave of the working frequency, the amplitude and phase can be set up at you wish. You also can make a harmonic analysis of the output value and draw a waveform graph.
● It can test the voltage, current, power stability and tri-phase total power stability of each unit automatically. It can display the comparative errors of the monitor meters and the tri-phase dissymmetry indexes of the output electric quantity (the devices equipped with digital standard meters).
● The devices have the features of high stability, good reliability and large output power. The voltage (current) loop can afford different type of loads.
● The devices have complete functions of breakdown examination, location, protection and warning, it avoids damage for artificial faults of connection or operation.
● PC software for Windows98 (Windows2000, WindowsXP) is written by Delphi5.Control devices and data queries are efficient. It also has the perfect functions of reports print, amount statistics and assets maintenance.

Technical Parameters:

Voltage Source:

1. Output voltage range: 30-300V(phase-neutral), 50-480V(phase-phase)

2. Output Max Power: 800VA

Range output power

57.7/63.5V 400VA

100/110V 400VA

220V/240V 400VA

380/415V 400VA

3. Resolution: 0.01%

4. Stability: Better than 0.05% / 3 Min(Time base 5S)

5. Distortion factor: < 0.5% at linear load;

6. Frequency range: 45Hz~65Hz;

7. Power efficiency: more than 85%;

8. Ambient temperature:10℃~50℃

9. Electronic overload and short-circuit protection.

Current Source:

1. Output current: range: 3×1mA~100A;+/-20%

2. Output maximum power: 2000VA

3. Resolution: 0.01%;

4. Stability:better than 0.05%/3 min(time base 5S);

5. Distortion factor: < 0.5% at linear load;

6. Frequency range: 45Hz~65Hz;

7. Power efficiency: greater than 85%;

8. Ambient temperature:10℃~50℃

9. Electronic overload protection and security for open current circuit.

Structure and main parts

Meter Test Bench Automatic Change To Calibrate / Test Line And Neutral 16 PositionsMeter Test Bench Automatic Change To Calibrate / Test Line And Neutral 16 Positions

① Error calculator ② Screw for tested meter

③ Bracket for tested meter

④ Keyboard / output display and signal generator

⑤ pulse input

  • power switch
  • current shortcut
  • phantom load power source

(voltage source amplifier and current source amplifier)

(voltage range shifter and current range shifter)


Product Tags:

Meter Testing Bench

      

Energy Meter Test equipment

      
China Meter Test Bench Automatic Change To Calibrate / Test Line And Neutral 16 Positions wholesale

Meter Test Bench Automatic Change To Calibrate / Test Line And Neutral 16 Positions Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ZHEJIANG YOMIN ELECTRIC CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0